A steel-plate-concrete (SC) composite wall is composed of steel faceplates, infill concrete, and connectors. The faceplates are joined with steel tie rods that ensure structural integrity. Steel studs are welded to the faceplates to ensure composite action.
* Windows Media Video streaming format. Internet Explorer recommanded.
H (cm) |
L (cm) |
T (cm) |
Tp (cm) |
flange thick (cm) |
reinforcement | fy (MPa) | f'c (kgf/cm2) |
Aspect ratio |
stud (cm) |
Tie (cm) |
S (cm) |
slenderness | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SC1 | 90 | 120 | 25.9 | 0.45 | 3 | 0.0347 | 300 | 210 | 0.75 | 0 | 11 | 11 | 24.44 |
SC2 | 90 | 120 | 25.9 | 0.45 | 3 | 0.0347 | 300 | 350 | 0.75 | 0 | 11 | 11 | 24.44 |
SC3 | 146 | 120 | 25.9 | 0.45 | 2 | 0.0347 | 300 | 210 | 1.22 | 0 | 11 | 11 | 24.44 |
SC4 | 146 | 120 | 32.9 | 0.45 | 2 | 0.0274 | 300 | 210 | 1.22 | 0 | 11 | 11 | 24.44 |